Skip to main content

GuidelinesBy procedure2026.11.15

Medical device e-Civil Service System, Integrated Information System and NIDS: where each task is done

MFDS online work for medical devices starts from a single address, emedi.mfds.go.kr. This guide sets out, by the task you want to do, what Ansim Chaekbang, the e-Civil Service System and the UDI Tracking Management System each handle, and which tasks go elsewhere, such as Government24, the performance reporting system and the training institutions.

Key takeaway As checked on 26 October 2026, MFDS online work for medical devices branches off from the emedi.mfds.go.kr front page. To look up information, go to Medical Device Ansim Chaekbang; to apply for approval, certification or notification and for changes and renewals, go to the Medical Device e-Civil Service System; for standard code registration and supply record reporting, go to the Medical Device UDI Tracking Management System. Sales, leasing and repair business notifications, performance reports and quality manager training are handled at other counters, not at these three.

The front page splits into four branches

When you access emedi.mfds.go.kr, the front page shows four shortcuts. Typing udiportal.mfds.go.kr also leads to the same front page. The menu names in the table below are taken as they appeared on screen on 26 October 2026.

Shortcut Main menus on screen
Medical Device Ansim Chaekbang (의료기기안심책방) Item and company search, attached document search, item validity period lookup, GMP inspection status, designated testing laboratories, devices subject to recall, administrative sanctions
Medical Device e-Civil Service System (의료기기전자민원시스템) Import approval, import notification, change approval, renewal, Class 1 medical device notification, Class 2 technical document review, investigational device confirmation, English-language medical device certificates, authenticity check of issued documents
Medical Device UDI Tracking Management System (의료기기UDI추적관리시스템) Customer management, report data registration, distribution record registration, UDI/EDI code lookup
Digital medical and health support devices (디지털의료·건강지원기기) Shortcuts to related information search and applications

The e-Civil Service System and the UDI Tracking Management System use the same 'integrated membership' sign-up on the front page. The personal information notice in the membership terms divides member types into individual, sole proprietor, corporation and medical institution. At the bottom of both system screens, the operating body is given as the National Institute of Medical Device Safety Information (NIDS).

Why there are several names

Article 31-3(1) of the Medical Devices Act calls the electronic information processing system that the Minister of Food and Drug Safety may build and operate "to efficiently record and manage information on medical devices from approval through manufacture, import, sale and use" the 'Integrated Medical Device Information System'. On screen, this name is not attached to just one place. It is also shown in the Ansim Chaekbang page title, and the membership terms also describe the service as the Integrated Information System.

So when you are told to 'process it in the Integrated Information System', it is quicker to first check which task is meant. The screens for information registration under Article 31-3(2) of the Act (standard codes and product information) and for supply record reporting are on the UDI Tracking Management System side. The UDI Tracking Management System front page shows both the integrated information registration status and the supply record reporting status. Supply record reporting covers not all medical devices but the devices specified in Article 54-2(1) of the Enforcement Rule. Registration deadlines and reporting scope are set out separately in the Integrated Medical Device Information System guide.

Some people search for it under the name 'Medical Device Information Portal'. This name appears on the slide buttons on the Ansim Chaekbang front page. If your aim is to look up information such as approval status, look in the Ansim Chaekbang menus.

Counters by task

The application counter and the body that actually receives the documents sometimes differ, so they are listed separately. The legislation in the basis column was checked against the text in force as of 26 October 2026.

Class and procedure do not map one to one. For manufacturing, Article 4 of the Enforcement Rule makes product-by-product manufacturing approval apply to Class 2 devices that are "medical devices not substantially equivalent in structure, principle, performance, intended use, method of use, etc. to medical devices already approved, certified or notified (excluding medical devices for export)". So being Class 2 does not automatically send you to the Institute's certification counter.

Task Where to apply or use Body receiving the documents Basis
Manufacturing or import business licence e-Civil Service System (visit and post also mentioned) Competent Regional Office of Food and Drug Safety Articles 6 and 15 of the Act, Articles 3 and 29 of the Enforcement Rule
Product approval (Classes 3 and 4, some Class 2) e-Civil Service System Minister of Food and Drug Safety Articles 4, 5(1) and 30(1) of the Enforcement Rule
Product certification (Class 2 devices designated by notice) e-Civil Service System President of NIDS Article 44(2) of the Act, Articles 4, 6(1) and 30(2) of the Enforcement Rule
Product notification (Class 1) e-Civil Service System President of NIDS Article 44(2) of the Act, Articles 4, 7(1) and 30(3) of the Enforcement Rule
Renewal of approval or certification e-Civil Service System 'Renewal' Minister of Food and Drug Safety or NIDS Article 62-2 of the Enforcement Rule
Standard code and product information registration, supply record reporting UDI Tracking Management System Supply reports go to the Minister of Food and Drug Safety (system operated by the Integrated Medical Device Information Center) Articles 31-2, 31-3 and 31-4 of the Act, Article 54-2 of the Enforcement Rule
Sales or leasing business notification Government24 City, county or district where the premises are located Article 17(1) of the Act
Repair business notification Government24 City, county or district Article 16(1) of the Act
Production, export, import and repair performance reports Korea Medical Devices Industry Association Internet Performance Reporting System Minister of Health and Welfare and Minister of Food and Drug Safety Articles 27 and 33 of the Enforcement Rule, performance reporting notice
Annual mandatory training for quality managers Training institution websites NIDS and others e-Civil Service System notice
Advertising self-regulatory review Self-regulatory review body Self-regulatory review body Article 25 of the Act

For sales and leasing business notifications, the business-type guidance in Ansim Chaekbang links to the Government24 application screen. The same guidance states that proxy applications cannot be made online, and that you should ask the public health centre with jurisdiction over the premises about the requirements before writing the notification (the guidance page's last content check date is shown as 2023-08-24). Cases where no sales business notification is needed are covered in the sales business notification guide, and leasing and repair businesses in the leasing and repair business notification guide.

For performance reports, an e-Civil Service System notice (posted 2026-10-14) gives the deadline and the counter. It says that medical device manufacturers, importers and repairers report the previous year's production, export, import and repair performance by 31 January each year through the Korea Medical Devices Industry Association Internet Performance Reporting System (bogo.kmdia.or.kr). The basis is Article 27 of the Enforcement Rule (manufacturers, production and export performance for the year), Article 33 (importers, import performance for the year) and the Regulation on Reporting Medical Device Production, Export, Import and Repair Performance (MFDS Notice No. 2025-74). Article 33 also contains a proviso that import performance need not be reported where a standard advance report for customs clearance has been filed as an electronic trade document under the Electronic Trade Facilitation Act.

There is also a notice on the same day about mandatory training for quality managers. It names the Pan-Ministry Integrated Healthcare Association (incorporated association, edu.kothea.or.kr) and NIDS (edu.nids.or.kr) as training institutions, and states that this year's training must be completed by 31 December. Completion can be checked in the Ansim Chaekbang 'mandatory training completion check' menu. Qualifications and the training obligation are set out in the quality manager guide.

Advertising self-regulatory review is applied for at a self-regulatory review body, and information on the system is in the Ansim Chaekbang 'advertising self-review' menu. For the media covered and the scope of exemptions, see the advertising review guide.

What to look at in Ansim Chaekbang before applying

Some information, if checked in Ansim Chaekbang before you write the application, cuts down on questions later. All of these are menu names on the screen as of 26 October 2026.

  • Item and company search: see under which item name and class similar products were approved, certified or notified. The search order is in the medical device status guide.
  • Attached document search: view attached documents such as the instructions for use of approved products.
  • Item validity period lookup: check the validity period of your item. Read it together with the approval renewal guide for renewal scheduling.
  • GMP inspection bodies · designated domestic and overseas testing laboratories: check which bodies can carry out inspections and tests.
  • Class 1 and 2 medical device supplementation cases: a board of supplementation cases in Ansim Chaekbang. Before receiving a supplementation request, you can see what issues were raised for the same class.
  • Devices subject to recall · administrative sanctions: check what problems occurred in the same product group.

What a company accessing for the first time should decide

Who signs up. Choose the integrated membership type that matches the applicant. Because the company's application history builds up in one officer's account, it helps to decide in advance how the account and applications in progress will be handed over when the officer changes.

Contact points. The help desks listed at the bottom of the screen are 1644-0222 for e-civil applications and membership, 1899-9351 for UDI and supply record reporting, and 1577-1255 for policy matters. All are marked as paid calls (checked 2026-10-26).

Screen errors. A UDI Tracking Management System notice says that many screen errors experienced by existing users are browser cache problems, and advises clearing the cache and reopening the browser before accessing again. If that does not work, enquiries are to be made through the 'usability Q&A' on the e-civil service website.

Three things that are often confused

Product notification and integrated information registration are separate. Even after a Class 1 notification certificate is issued, standard code and product information registration is done separately in the UDI Tracking Management System. Obligations after notification are in the Class 1 UDI and supply record reporting guide.

Sales business notification goes to the city, county or district, not to the MFDS system. Article 17(1) of the Act names the recipient of the notification as the mayor of the special self-governing city, the governor of the special self-governing province, or the head of the city, county or district where the premises are located.

Performance reports go to the association's system. Rather than looking for a performance reporting menu in the e-Civil Service System, it is quicker to go straight to the Internet Performance Reporting System named in the notice.

If you are unsure which counter and which procedure the task you are preparing belongs to, put together your product documents and current stage and request a preliminary review. We will send a first reply within 1 business day.

Official sources: Medical Devices Act Articles 6, 15, 16, 17, 25, 31-2, 31-3, 31-4 and 44 (current text checked 2026-10-26) · Enforcement Rule of the Medical Devices Act (Ordinance of the Prime Minister No. 2127, effective 1 July 2026) Articles 3, 4, 5, 6, 7, 27, 29, 30, 33, 54-2 and 62-2 · Regulation on Reporting Medical Device Production, Export, Import and Repair Performance (MFDS Notice No. 2025-74) · Medical Device Ansim Chaekbang, e-Civil Service System and UDI Tracking Management System screens and notices · National Institute of Medical Device Safety Information business information. Screens checked: 2026-10-26. System addresses and menu names may change, and for individual applications the guidance of the receiving and processing body takes precedence.

Frequently asked questions

Q. How do I access the medical device e-Civil Service System?
As checked on 26 October 2026, enter through the 'Medical Device e-Civil Service System' shortcut on the emedi.mfds.go.kr front page. Typing udiportal.mfds.go.kr also leads to the same front page. Screen addresses and menu names can change, so check the front page again each time you access it.
Q. Are the Integrated Medical Device Information System and the UDI Tracking Management System the same thing?
Article 31-3 of the Medical Devices Act calls the electronic information processing system that records and manages medical device information from approval through to use the Integrated Medical Device Information System. On screen, this name is also used in the Ansim Chaekbang page title and in the membership terms, so it does not point to a single screen. The screens for registering standard codes and product information and for supply record reporting are on the UDI Tracking Management System side.
Q. Is a sales business notification also filed in the medical device e-Civil Service System?
Sales business and leasing business notifications are made to the mayor of the special self-governing city, the governor of the special self-governing province, or the head of the city, county or district where the business premises are located (Article 17(1) of the Medical Devices Act). The business-type guidance in Ansim Chaekbang also links online applications to Government24 (checked 2026-10-26).
Q. What does the National Institute of Medical Device Safety Information do?
Under Article 44(2) of the Medical Devices Act, it is entrusted with medical device certification and notification work and receives Class 2 certification and Class 1 notification documents (Articles 6, 7 and 30 of the Enforcement Rule). The business information on the Institute's website also lists operation of the Integrated Information System (UDI), collection and analysis of safety information such as adverse events, and training for quality managers (checked 2026-10-26).

Just send the product details.
We do the reviewing.

We pre-review device class, required pathway, and data readiness free of charge, and reply within 1 business day. No sign-up.